Appliance Types


Appliance Brands


Article Categories


More Articles


Tempstar Appliances
Tempstar Appliances

Tempstar Appliance Repair

When you choose Tempstar heating and cooling equipment, you're choosing enhanced dependability and innovation in home comfort. They are proud to give you the latest in engineering and technology. Their products are designed to deliver the best in quality, energy efficiency and reliability, and each is 100% run tested. They take pride in surpassing your expectations and delivering quality you can feel.


Air Conditioner Repair

Tempstar manufactures appliances that homeowners have come to trust. Even a trustworthy appliance requires occasional maintenance or repair, however. If you’re in need of Tempstar appliance repair from experienced professionals, your local Appliance Helper can help.

Tempstar Central air conditioner not cooling 
The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor is defective, it will not provide voltage to the condensing unit. To determine if the contactor is at fault, use a multimeter to test the contactor for continuity. If the contactor does not have continuity, replace it. 

Tempstar Central air conditioner is noisy or loud 
The condenser fan motor has bearings that can wear out over time. When the bearings are worn out, they make loud noise. To check the bearings, try rotating the condenser fan motor by hand. If the motor does not turn smoothly, replace it. 

Tempstar Condenser fan motor does not run 
If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it. 

Tempstar Condensing unit does not run 
The wall thermostat has contacts in it that control the furnace. If the contact fails it can result in the furnace & condenser unit to not run at all.


Furnace Repair

Tempstar manufactures appliances that homeowners have come to trust. Even a trustworthy appliance requires occasional maintenance or repair, however. If you’re in need of Tempstar appliance repair from experienced professionals, your local Appliance Helper can help.

Tempstar Furnace not heating 
The igniter gets very hot and glows bright orange to light the gas burner. If the igniter fails or cracks, the furnace won’t heat. To determine if the igniter is faulty, remove the igniter and inspect it for cracks. If the igniter is cracked, replace it. If the igniter is not cracked, use a multimeter to test the igniter for continuity. If the igniter does not have continuity, replace it. 

Tempstar Furnace is noisy or loud 
The blower wheel blows air out of the furnace and through the house. The blower wheel is attached to the blower motor shaft with a set screw. If the set screw is loose, the blower wheel will wobble on the motor shaft, and the wheel will be noisy as it turns. Check the set screw to ensure that it is properly tightened. Next, inspect the wheel for damage. If the blower wheel is damaged, replace it. 

Tempstar Furnace starts then stops 
The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, it might fail to detect a flame. If the flame sensor does not detect a flame, the control board will shut off voltage to the gas valve to prevent the furnace from heating. Sometimes, if the flame sensor is dirty, it will fail to detect a flame. Try cleaning the flame sensor with a fine abrasive pad. If the furnace still doesn’t heat, replace the flame sensor. 

Tempstar Furnace blower not running 
The blower motor blows air through the return vent, past the heat exchanger, and into the home’s venting. First, make sure that power is getting to the motor. If power is getting to the blower motor, but the motor does not run, the motor may be burned out. If the blower motor is burned out, replace it. If the blower motor hums, check the blower fan to ensure that it spins freely. If the blower fan is unobstructed but does not spin freely, replace the blower motor. 

Tempstar Furnace blower runs all the time 
The control board has relays that regulate the voltage to each component in the furnace. If the relay that controls the blower motor fails while it is closed, it will send continuous voltage to the blower motor, causing the motor to run continuously. If the control board is at fault, replace it.



Tempstar Appliance Repair

Tempstar appliance service

Tempstar appliance help

Tempstar appliance assistance

Tempstar appliance maintenance


Product Reviews:

We have two zonal Tempstar central hvac units that were installed in 1995â€
We have two zonal Tempstar central hvac units that were installed in 1995…have never really ever been serviced and are still going strong what can I say.
Published: July 8, 2017
WC Geeslin
Source: furnacecompare.com

I'd like to say that I am very satisfied with this Tempstar brand 99.9
I'd like to say that I am very satisfied with this Tempstar brand 99.9% of the issues that we end consumers have with our systems is due to poor installation by individuals that are not properly qualified to do the job. Anyone with common sense will know that that goes the same for any other product out there. This Tempstar unit that I have installed in my home tsa 6 – 16 seer is a super quiet and yet out performed my old Goodman I recommend this manufacturers brand which of whom is essentially a Carrier product doing my research ICP cooperation makes Carrier, Bryant, Tempstar, day night, Payne and their product is also under a number of names as well. They are all the same equipment different models different metal exterior designs however the equipment compressors and system components are exactly the same with all the different brands at which they make again this is doing my research once again I am 100% satisfied with my Tempstar I believe those of us that have the bad experience and leave really bad reviews are due to very poor installation of the equipment by unqualified individuals.. Hope this is helpful to any and everyone out there!!
Published: October 31, 2017
Brian Omaha,NE
Source: furnacecompare.com

Tempstar delivers a consistent range of high-performance products and multi
Tempstar delivers a consistent range of high-performance products and multiple options for energy efficiency ratings. Tempstar customers also benefit from comprehensive warranty coverage at affordable pricing.
Published: November 9, 2020
furnaceprices.ca
Source: furnaceprices.ca

I hired a very able company and had them remove my 12-year-old Rheem furnac
I hired a very able company and had them remove my 12-year-old Rheem furnace. I paid $2500 for a Tempstar-Heil single stage N9MSE furnace for use with propane. I've only had the unit for a few weeks but so far it's working perfectly, keeping my home within one degree of thermostat settings. It's possibly a bit quieter than the Rheem but I'm not sure any single stage unit can be non-intrusive when they run. Bottom line is that for $2500 installed I'm happy, and with the warranty this home should be warm for many winters to come…I hope.
Published: December 31, 2015
Joe Northeast PA
Source: furnacecompare.com

I bought my house in may 2002. It had a temp star 10 (rated seer 10) five t
I bought my house in may 2002. It had a temp star 10 (rated seer 10) five ton nac060aka1 central ac with gas heating. The compressor is mounted on a concrete pad outside my house. The ac is a split unit with the heater mounted inside the house in the attic space with the other haft of the ac unit called a coil. The fan above the compressor was replaced last year ant the compressor disconnect was replaced at that time. I have not done any maintenance or other repair. The service repair man said the compressor is running two amp more than normal causing the disconnect terminals to overheat that cause the it to be replaced. the higher amperes are an indication that compressor will be failing soon. that was 15 months ago. He said that the unit used Freon R 11 which will be phase out soon and that the entire ac central ac unit would need replacement. The new AC units are rated 13 seer which the dept. of energy say is 40 percent better than a seer 10. so replacing it will be okay with me. The Tempstar 10 lasted 15 years and is still running- that's pretty good life. I have no complaints
Published: November 4, 2017
Anthony Vidana
Source: furnacecompare.com

Have a 2 stage 95% efficiency condensing Tempstar furnace, installed by sel
Have a 2 stage 95% efficiency condensing Tempstar furnace, installed by self and careful old contractor. Gas bills dropped 25 to 30%, temperature in house much more even and comfortable at a lower thermostat setting. Has ran fine for 5 years, regular maintenance of condensing drain system, trap and line is a must with these units, watch for leaks etc. Also have a high quality electrostatic intake filter, which I clean regular, as well as the fan compartment. People probably put the cheapest filter they can find in a $3000 furnace no doubt, but not smart. This sort of care takes a few minutes now and then but pays off handsomely in maintenance bills.
Published: December 5, 2015
Randy
Source: furnacecompare.com

3 ton 16 seer heat pump 15 kw heat pack and it's been awesome. All I c
3 ton 16 seer heat pump 15 kw heat pack and it's been awesome. All I can say is, treat the guys doing your install like family and they will do you a good job. I feed them supper and we watched a movie after. I live in Waco, TX. It gets very hot here. It was 113 last week with 60% humidity. We keep the air on 65 and it has no problem. It cycles on and off like normal. Our energy bill went from $340 to $360. Now it's $120 to $130.
Published: August 5, 2018
Christian Texas
Source: furnacecompare.com

I have had four different units at my house live there for 50 years Tempsta
I have had four different units at my house live there for 50 years Tempstar has been there and is cooled the best for the past 5 years.
Published: April 20, 2018
Bill Carter
Source: furnacecompare.com

I've been living in my apartment for almost five years now, so I know
I've been living in my apartment for almost five years now, so I know the ins and outs of this furnace, though it's hard to know how much the furnace is to blame or the duct-work and insulation. It keeps the house warm and the bills pretty low. That's pretty much my only concern in a furnace. If I had any complaints about it, then those are basically that it doesn't seem to have a fast pick up.
Published: November 16, 2015
Buffalo, NY
Source: furnacecompare.com

Tempstar air conditioners are high-quality, durable, and reliable, and the
Tempstar air conditioners are high-quality, durable, and reliable, and the company backs their products with one of the best air conditioner warranties in the industry. There are plenty of models to choose from in the Tempstar lineup. Many of them have great efficiency ratings, so you’ll save money by upgrading to a more energy-smart cooling system.
Published: December 8, 2019
furnaceprices.ca
Source: furnaceprices.ca

Visa MasterCard

Site Secured By The Website Guardian
TOP