Ducane products are built to last and lab tested for dependability. Each one is designed to deliver reliable comfort while helping you save money. No matter what the weather or season, Ducane is always the right choice.


Air Conditioner Error Codes

CODE: POWER (Green). 
PROBLEM: Module has power 
FIX: Supply voltage is present at module terminals. 

CODE: TRIP (Red). 
PROBLEM: Thermostat demand signal Y1 is present, but the compressor is not running 
FIX: 1. Compressor protector is open - Check for high head pressure - Check compressor supply voltage 2. Outdoor unit power disconnect is open 3. Compressor circuit breaker or fuse(s) is open 4. Broken wire or connector is not making contact 5. Low pressure switch open if present in system 6. Compressor contactor has failed open. 

CODE: ALERT (Yellow) Flash Code 1. 
PROBLEM: Long Run Time Compressor is running extremely long run cycles 

CODE: ALERT (Yellow) Flash Code 2. 
PROBLEM: System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded 
FIX: 1. High head pressure - Check high pressure switch if present in system - Check if system is overcharged with refrigerant - Check for non-condensable in system 2. Condenser coil poor air circulation (dirty, blocked, damaged) 3. Condenser fan is not running - Check fan capacitor - Check fan wiring and connectors - Check fan motor for failure or blockage 4. Return air duct has substantial leakage 5. If low pressure switch present in system, check Flash Code 1 information. 

CODE: ALERT (Yellow) Flash Code 3. 
PROBLEM: Short Cycling Compressor is running only briefly 
FIX: 1. Thermostat demand signal is intermittent 2. Time delay relay or control board defective 3. If high pressure switch present, go to Flash Code 2 information 4. If low pressure switch present, go to Flash Code 1 information. 

CODE: ALERT (Yellow) Flash Code 4. 
PROBLEM: Locked Rotor 
FIX: 1. Run capacitor has failed 2. Low line voltage (contact utility if voltage at disconnect is low) - Check wiring connections 3. Excessive liquid refrigerant in compressor 4. Compressor bearing are seized 5. Measure compressor oil level. 

CODE: ALERT (Yellow) Flash Code 5. 
PROBLEM: Open Circuit 
FIX: 1. Outdoor unit power disconnect is open 2. Compressor circuit breaker or fuse(s) is open 3. Compressor contactor has failed open - Check compressor contactor wiring and connectors - Check for compressor contactor failure (burned, pitted, or open) - Check wiring and connectors between supply and compressor - Check for low pilot voltage at compressor contactor coil 4. High pressure switch is open and requires manual reset 5. Open circuit in compressor supply wiring or connections 6. Unusually long compressor protector reset time due to extreme ambient temperature 7. Compressor windings are damaged - Check compressor motor winding resistance. 

CODE: ALERT (Yellow) Flash Code 6. 
PROBLEM: Open Start Circuit. Current only in run circuit 
FIX: 1. Run capacitor has failed 2. Open circuit in compressor start wiring or connections - Check wiring and connectors between supply and the compressor S terminal 3. Compressor start winding is damaged - Check compressor motor winding resistance. 

CODE: ALERT (Yellow) Flash Code 7. 
PROBLEM: Open Run Circuit. Current only in start circuit. 
FIX: 1. Open circuit in compressor run wiring or connections - Check wiring and connectors between supply and the compressor R terminal 2. Compressor run winding is damaged - Check compressor motor winding resistance. 

CODE: ALERT (Yellow) Flash Code 8. 
PROBLEM: Welded Contactor. Compressor always runs 
FIX: 1. Compressor contactor has failed closed 2. Thermostat demand signal not connected to module. 

CODE: ALERT (Yellow) Flash Code 9. 
PROBLEM: Low Voltage. Control circuit less than 17VAC 
FIX: 1. Control circuit transformer is overloaded 2. Low line voltage (contact utility if voltage at disconnect is low) - Check wiring conditions.


Furnace Error Codes

CODE: LED off. 
PROBLEM: No power to control or control hardware fault detected. 

CODE: LED on. 
PROBLEM: Normal operation. 

CODE: 1 Flash. 
PROBLEM: Flame present with gas valve off. 

CODE: 2 Flashes. 
PROBLEM: Pressure switch closed with inducer off. 

CODE: 3 Flashes. 
PROBLEM: Low fire pressure, rollout or aux limit switch open. 

CODE: 4 Flashes. 
PROBLEM: High limit switch open. 

CODE: 5 Flashes. 
PROBLEM: Not used. 

CODE: 6 Flashes. 
PROBLEM: Pressure switch cycle lockout. 

CODE: 7 Flashes. 
PROBLEM: Lockout due to no ignition. 

CODE: 8 Flashes. 
PROBLEM: Lockout due to too many flame dropouts.



Ducane Appliance Error Codes

Ducane appliance fault codes

Ducane appliance diagnostic codes

Ducane appliance error symbols

Ducane appliance common faults


Product Reviews:

Very pleased with recent complete A/C purchase. Unit works exceptionally we
Very pleased with recent complete A/C purchase. Unit works exceptionally well. The technician, Azi, did a great job installing & explaining functions of the unit. He was very courteous & professional during entire process. Highly recommend!
Published: November 1, 2020
JOHN
Source: ducanehvac.com

My last furnace died down in last year’s winter and I wanted something be
My last furnace died down in last year’s winter and I wanted something better. I did a quick internet search and was impressed by the reviews on Ducane Gas Furnaces. I immediately purchased the furnace and had it installed. So far, I’m so impressed with this furnace. It heats quickly, runs well, and has saved me quite some amount of energy bill in comparison to my old one. If I were to make another purchase, I would still go for Ducane.
Published: September 1, 2020
pickhvac.com
Source: pickhvac.com

We purchased this unit back in 2014. It was a replacement to our previous g
We purchased this unit back in 2014. It was a replacement to our previous gas furnace, which we had been using for more than twenty years. This unit is noticeably quiet and provides a cool and comfortable environment. With this unit, our energy costs are notably lower and so is the energy consumption. The variable quality allows it to run slowly with enough heat. This one is clearly among the best.
Published: November 1, 2020
pickhvac.com Phoenix, AZ
Source: pickhvac.com

When my old furnace needed replacement in the fall of 2013, I was quite sur
When my old furnace needed replacement in the fall of 2013, I was quite sure that I was going to buy the same brand yet again. I had lived in the house for more than twenty years and never had to repair the Ducane Gas Furnace. It heats our home in a short time and has significantly lowered our gas and energy bills. I’ve had no issues with it but I’ve had it checked and serviced every year to ensure that it continues to deliver optimally.
Published: October 1, 2020
pickhvac.com Cedar, MN
Source: pickhvac.com

Both AC units are performing better than expected. In 90+ degree weather, m
Both AC units are performing better than expected. In 90+ degree weather, my home is extremely cool. I'm very pleased.
Published: July 17, 2020
WALTER
Source: ducanehvac.com

Rated this 4 stars only because I wish it was quieter than it is when opera
Rated this 4 stars only because I wish it was quieter than it is when operating. It replaced a 14 year old condenser with a failed compressor. The new unit is only marginally quieter than the old unit.
Published: October 1, 2020
JOHN
Source: ducanehvac.com

I am very happy with this unit that I purchased definitely worth the money
I am very happy with this unit that I purchased definitely worth the money . Keeps my house nice and comfortable and that's very important here in South Texas.
Published: November 7, 2020
RAM
Source: ducanehvac.com

This unit is horrible! I had two of the Ducane units installed at both side
This unit is horrible! I had two of the Ducane units installed at both sides of my home less than four years ago. Both models freeze regularly and bring water in my home. I live in Arizona where we experience a lot of dust and so their filters require replacement in every three to four weeks. They are also noisy and I haven’t noticed any difference in the temperature of my home. It is a total waste of money. This unit is horrible! I had two of the Ducane units installed at both sides of my home less than four years ago. Both models freeze regularly and bring water in my home. I live in Arizona where we experience a lot of dust and so their filters require replacement in every three to four weeks. They are also noisy and I haven’t noticed any difference in the temperature of my home. It is a total waste of money.
Published: August 1, 2020
pickhvac.com Calgary, AB
Source: pickhvac.com

I am so angry at my husband for purchasing this model. The power vent motor
I am so angry at my husband for purchasing this model. The power vent motor in this furnace died in less than a year of use and three months later I was required to change the ignitor and gas valve. It seems like everything is wrong with this Ducane. It vibrates and sounds like a train when on. When I called the technician about the issues, they said that it was normal and I had no cause for alarm. This Ducane unit is so bad I don’t even know what more to say.
Published: July 1, 2020
pickhvac.com Zionsville, IN
Source: pickhvac.com

So far our new Air conditioner is working great. Our installer was very pro
So far our new Air conditioner is working great. Our installer was very professional and communicated with us every stepbof the way. Simply Stellar. A huge Thank you to American Air & Appliance. We recommend American Air & Appliance to anyone nerding Service work or an entirely new AC & heating unit.
Published: October 12, 2020
RALEIGH
Source: ducanehvac.com

Visa MasterCard

Site Secured By The Website Guardian
TOP