Appliance Types


Appliance Brands


Article Categories


More Articles


FibroPool Appliances
FibroPool Appliances

FibroPool Appliance Troubleshooting

Established in 2002, FibroPool designs and manufactures equipment and hardware for the swimming pool industry. We take pride in utilizing industry leading technologies to create some of the most energy-efficient and user friendly products on the market.


Pool Heaters Troubleshooting

Have you cleaned your filter lately? 
• Monitor your PSI reading on your filter’s pressure gauge. If the PSI is too high, clean your filter. 
• Increasing pressure goes hand in hand with the decrease of water flow. 

Is your pump basket dirty? 
• Check your pump’s strainer basket. Remove the basket and remove the debris with a hose. 
• Ensure the pump basket and lid are in good conditions. No cracks. 

Do you have too many water features operating at once? 
• Your pool pump only moves a certain number of GPMs, therefore, too many water features can dramatically decrease your water flow. 
• If possible, replace the motor with a larger one. 
• Close water features, or alternate them, until the pool heats to the desired temperature. 

Defective Pressure Sensor/switch  
• The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on. 
• The pool pump must be ON and your filter clean for the switch to close and allow voltage to pass through. 
• Test the voltage reading on the pressure switch with a multimeter. 
• Replace the pressure switch if necessary.

Are you using the low settings on your variable speed pump? 
• For operation, heaters require a minimum GPM flow. If you are running your variable speed pump on the low setting, make sure you meet the minimum GPMs for your heater. 

Is your pool water chemistry consistently and accurately balanced? 
• Poor water chemistry is one of the leading causes of equipment failure, especially pool heaters. 
• Test your water before adjusting your chemical levels. If unsure, please refer to the heater’s manual for the recommended chemical levels. 

Have you inspected the pressure sensor, thermal regulator, and/or the high limit switch? 
• Inspect these parts for corrosion, scaling, and/or any electrolysis issues. 
• If the pressure sensor, thermal regulator, or high limit switch is faulty, corroded, or defective - replace it. 

Have you cleaned your filter? 
• A dirty filter can cause low pressure and as a result, cause the heater’s pressure switch to turn OFF. A dirty filter can prevent a heater from firing and it can also cause your heater to shut off before warming the water to the desired temperature. 

When’s the last time you have inspected and cleaned the heat exchanger? 
• Deterioration of the heat exchanger can impact your heater’s operation. Inspect your heat exchanger for chemical or sanitizer damage.



FibroPool Appliance Troubleshooting

FibroPool appliance problems

FibroPool appliance broken

FibroPool appliance issue

FibroPool appliance difficulty


Product Reviews:

I live in Tennessee where the summers are hot with 90+ temps. The problem i
I live in Tennessee where the summers are hot with 90+ temps. The problem is my 18,000 above ground pool is in the shade most of the day and the water temp only reaches about 75. I needed something to get the temp above 82 but I didn't want an expensive gas heater or a problematic solar heater. Even though this heater pump is for a much smaller pool I thought I would give it a try since I only needed to raise the temp within 10 degrees. I've had it installed all summer and it works great when the night temps are above 70. When the nights drop below 70 I will put the solar cover on to trap the heat in. Great price and an easy to install. BTW my electric bill has only increased about $40 a month.
Published: September 4, 2019
Teresa M Rowland
Source: amazon.com

This pool heater is excellent. We love it. The support for this product was
This pool heater is excellent. We love it. The support for this product was fantastic. A+ to FibroPool. I had to call them because when I plugged it in, the display didn’t light up. They walked me through opening the panel on the side, finding a disconnected wire connector and plugging the little connector into the motherboard and wham, it was then working perfectly.
Published: July 7, 2020
Tim in Boston
Source: amazon.com

So far this product is great. As far as hooking up to a Intex pool with 1.5
So far this product is great. As far as hooking up to a Intex pool with 1.5" hoses was easy with the use of GAME 4560 40mm to 1 1/2 Inch Conversion Kit (For Intex & Bestway Pools) $9.59 . Did find out the only way that I was able to stop the leaks from the adapter was to replace the factory gaskets with 1.5" neoprene gaskets from True Value Hardware.
Published: September 28, 2019
Kindle Reader
Source: amazon.com

We were in the heater market for our 24x12/7000 gal above ground pool...thi
We were in the heater market for our 24x12/7000 gal above ground pool...this was new but we decided to try it...the 110 v plug in and price appealed to us, let me start off by saying that it was ridiculously easy to install, we didn't have to hire an electrician to run 220 out to our yard(as with all other pool heat pumps). I'd say all in all it took about 30 minutes to complete.
Published: May 10, 2019
Kathy Harned
Source: amazon.com

We have tried everything available to heat up our 18x 52 Intex metal post p
We have tried everything available to heat up our 18x 52 Intex metal post pool. We have had the pool for over 12 years and love it!. However, we don’t get to use it as much as we would like because the kids would complain that it is too cold. We moved to a new place that has a very shaded back yard. We only get sun on the pool from 11 am to 2pm. We resorted to buying the kids wetsuits so they could swim!
Published: July 31, 2019
KMK2CENTS
Source: amazon.com

Visa MasterCard

Site Secured By The Website Guardian
TOP