Appliance Types
- Air Conditioner
- Automobile
- Chainsaw
- Circular Saw
- Dishwasher
- Drills
- Dryer
- Drywall Screw Gun
- Furnace
- Gas Fireplace
- Gas Grill
- Gas Patio Heater
- Grinder
- Heat Pump
- Impact Driver
- Impact Wrench
- Microwave
- Nailer
- Orbital Sander
- Pool Heaters
- Powerwall
- Range
- Refrigerator
- Television
- Washer
- Water Heater
Appliance Brands
- A.O. Smith
- AccuCold
- Admiral Craft
- AGA
- Airrex
- Amana
- Ambiance
- American Range
- American Standard
- American Water Heaters
- Aquacal
- Armstrong
- Asko
- Avanti
- Avenlur
- Azure
- Beko
- Bellfires
- Bertazzoni
- Blackstone
- Blaze
- Blomberg
- BlueStar
- Bosch
- Bradford White
- Bromic
- Bryant
- Cafe
- Calcana
- Capital
- Carrier
- Char-Broil
- Char-Griller
- Chrysler
- Coates
- Coleman
- Comfortmaker
- Commercial Chef
- Continental
- Cosmo
- Cove
- Crown Verity
- Dacor
- Daikin
- Danby
- Danfoss
- DaVinci
- DCS
- Deco
- DeWALT
- Ducane
- Dyna-Glo
- Dyson
- EcoSmart
- Electrolux
- Element4
- Empava
- Equator
- Eurodib
- European Home
- Everdure
- Farberware
- Fhiaba
- FibroPool
- Fire Sense
- Fisher
- FiveStar
- Flare
- Flash Furniture
- Focus
- Ford
- Forno
- Forte
- Frigidaire
- Fulgor Milano
- Gaggenau
- GE
- General Motors
- GlowBrand
- Goodman
- Grundig
- GSW
- Haier
- Hayward
- Heatstar
- Heil
- Hestan
- Hisense
- Hitachi
- Hotpoint
- iio
- Ilve
- Impecca
- Ingignia
- Insignia
- JennAir
- John Wood
- Keeprite
- Kenmore
- Kenyon
- KitchenAid
- Kucht
- La Cornue
- Lennox
- LG
- Liebherr
- Lifetime
- Lion
- Luxaire
- Lynx
- Magic Chef
- Marvel
- Maytag
- McQuay
- MicroFridge
- Midea
- Miele
- Migali
- Monogram
- Montigo
- Mr Heater
- Napoleon
- Navien
- Nexgrill
- Noritz
- Panasonic
- Patio Comforts
- Payne
- Pentair
- Perlick
- PITT
- Premier
- Raypak
- Real Fyre
- Regency
- Reliance
- Rheem
- Rinnai
- Roma
- Ruud
- Saber
- Samsung
- Schwank
- Sharp
- Smeg
- Solas
- Sony
- Spartherm
- Speed Queen
- StaRite
- State Water Heaters
- Stiebel Eltron
- SubZero
- Summerset
- Summit
- SunGlo
- SunPak
- Sunpentown
- SunStar
- Superiore
- Takagi
- TCL
- TEC
- Tempstar
- Tesla
- Thermador
- Thor Kitchen
- Toshiba
- Town and Country
- Toyota
- Traeger
- Trane
- Twin Eagles
- U-Line
- Unique
- Vaillant Group
- Valor
- Verona
- Victory
- Viessmann
- Viking
- Vizio
- Weber
- Westinghouse
- Whirlpool
- Whynter
- York
- ZLINE
Article Categories
- Air Conditioners
- Appliance Care
- Appliance News
- Dishwasher News
- Drying Machines
- Furnaces
- Gas Fireplaces
- Microwaves
- Pool Heaters
- Refrigerators
- Stoves - Ranges
- Tips and Tricks
- Washing Machines
- Water Heaters
More Articles
Viessmann Heat Pump Model VITOCAL 300-G Pro
Large Source VITOCAL 300-G Pro
Large heat pump.
Ground source heat pump with the option of water/water operation with intermediate brine circuit.
Vitocal 300-G Pro, ground source heat pumps for large residential and commercial buildings.
The Vitocal 300-G Pro heat pumps with up to 222.2 kilowatts are manufactured in series. The Pro series features all the characteristics of the highly efficient Vitocal 300-G series. With five output sizes, most requirements from residential and commercial buildings can be reliably met. These appliances are standardised, enabling quick and comprehensive system design, as well as transparent cost calculation parameters. Higher output levels can be achieved by linking up to five Vitocal 300-G Pro in a cascade.
Easy to operate Vitotronic control unit with plain text and graphic display.
The Vitotronic 200 regulates up to three heating circuits and, thanks to its natural cooling function, ensures a pleasant indoor environment on hot summer days. An extensive range of monitoring and system optimisation settings can be adjusted from anywhere, via the internet or a smartphone, utilising the Vitocom 300 communication module that is available as an option.
Combination with air/brine heat exchanger.
In conjunction with an air/brine heat exchanger, the Vitocal 300-G Pro offers both cooling operation and the use of air as a heat source. The air/brine heat exchanger is connected to the heat pump via a brine circuit and enables heat recovery at an air temperature of down to -5 °C. Below -5 °C, a second heat generator takes over the heat supply in dual alternative mode. This allows for flexible system design and the formation of a robust system together with a second heat generator.
For such air/water applications, both the Vitocal 300-G Pro and the air/brine heat exchanger designed for this purpose are available. An attractive solution from a single source.
Manufacturer: Viessmann
MODEL: VITOCAL 300-G Pro
MSRP: $5000.00 USD
Viessmann Heat Pump Model VITOCAL 300-G Pro Error Codes
Viessmann heat pumps may display error codes to indicate specific issues with the system. It's important to consult the specific documentation provided by Viessmann for your heat pump model, as error codes can vary. Below are some common Viessmann heat pump error codes and their potential meanings:
Fault Code F0:
This code may indicate a flow or circulation issue. Check if the pump is functioning correctly and if there are any obstructions in the system.
Fault Code F1:
This code is often related to a sensor or temperature issue. It may indicate a fault with the temperature sensor or a problem with the system's heat exchanger.
Fault Code F2:
F2 may suggest a refrigerant pressure issue. This could be related to low refrigerant levels or problems with the pressure sensors.
Fault Code F4:
F4 is associated with a compressor issue. It may indicate a problem with the compressor motor or its components.
Fault Code F7:
F7 may indicate a fault with the outdoor fan motor. This could be related to issues with the motor or its connections.
Fault Code F8:
F8 is often associated with a defrosting issue. It may indicate a problem with the defrost sensor or the defrosting system.
Fault Code F9:
F9 may suggest a fault with the water pump. Check if the pump is operating properly and if there are any issues with water circulation.
Fault Code FA:
FA is associated with an automatic reset. The system may have encountered a temporary issue, and the automatic reset is attempting to resolve it.
It's crucial to refer to the specific user manual or technical documentation provided by Viessmann for your heat pump model to interpret error codes accurately. If you encounter an error code and are unsure about its meaning or how to address it, it's recommended to contact Viessmann's customer support or a qualified technician for assistance. Attempting to resolve complex issues without proper knowledge can lead to further problems.
Related Error Code Pages:
Viessmann Heat Pump Error Codes,
Related Troubleshooting Pages:
Viessmann Heat Pump Troubleshooting,
Related Repair Pages:
Viessmann Heat Pump Repairs,
Related Parts Pages:
Viessmann Heat Pump Parts,
Viessmann Heat Pump Model VITOCAL 300-G Pro
I love my new Vitocal heat pump so much! Installed by Heat Different, it looks great, and the Viessmann app is so easy to use. The hot water is always ready to use at just the right temperature, and I am using a quarter of the energy and creating no carbon thanks to a Green tariff. Goodbye polluting gas boiler, hello livable future for the planet! Thank you Viessmann for a quality product.
Would like to know more information on getting fault codes cleared on my air source heat pump. Codes F.793 and F.792. Was told by my installer that Viessmann would carry out a software update and this would clear these codes as the unit is continually flashing red. Apart from that very happy with our new heating system.
No Hot Water / Heating, for over a week. kept getting F2 fault. service engineer said not to use it, he also said it needed a new pump which didn't make any sense. I phoned Viessmann on a few occasions expressing my concern that we had to wait over a week for a part I didn't think it needed anyway but still had to wait a week for the next engineer who actually worked for Viessman he agreed it was unlikely to be the pump and it ended up some plate that needed cleaning. The 111-W boiler is now fixed at a cost but unhappy that we was fobbed off for a week with no hot water or heating.
Air source Heat pump Viessmann 100A PCB failure fault evident at installation. Taken 9 months to have this corrected. Cost for fault 2 months €600 euros 2 Bed terrace house with only one occupant. There are approximately 25 plus houses on site with the same fault. legionella system faulty.
Great experience with Viessmann - had a regular service which went well, but unfortunately uncovered another issue immediately afterwards leaving us with no hot water. Viessmann got a remedial visit sorted the next day and now all working again. Shout out to our engineer Chris Brown who fixed it, did a great job, explained everything that had happened - thanks! Also had a good chat about the future of heat pumps, batteries etc.