CODE: E01  
PROBLEM: No communication between remote controller and indoor unit. 

CODE: E02  
PROBLEM: Local controller failure - unable to transmit.

CODE: E03  
PROBLEM: Master indoor unit receives no data to A-B.

CODE: E04  
PROBLEM: Indoor unit receives no communications from outdoor unit.

CODE: E08  
PROBLEM: Duplicated indoor unit address. 

CODE: E09  
PROBLEM: 2 local controllers connected on a group - both configured as masters. 

CODE: E10  
PROBLEM: Indoor unit PSB failure. 

CODE: E18  
PROBLEM: Communications failure between master indoor unit and slave indoor unit or units. 

CODE: F01  
PROBLEM: Indoor unit TCJ (Liquid) sensor error. 

CODE: F02  
PROBLEM: Indoor unit TC2 (Vapor) sensor error. 

CODE: F04  
PROBLEM: Outdoor unit TD (Discharge) sensor error. 

CODE: F06  
PROBLEM: Outdoor unit TE (Coil) sensor error.  

CODE: F08  
PROBLEM: Outdoor unit TO (Ambient) sensor error. 

CODE: F10  
PROBLEM: Indoor unit TA (Return Air) sensor error.  

CODE: F29  
PROBLEM: Indoor unit PCB failure. 

CODE: H01  
PROBLEM: Outdoor unit inverter compressor over current detected. 

CODE: H02  
PROBLEM: Master outdoor unit over current detected shortly after start up. 

CODE: H03  
PROBLEM: Current detected on Master outdoor unit whilst idle. 

CODE: H06  
PROBLEM: Outdoor unit Low pressure detected by sensor.

CODE: L03  
PROBLEM: Indoor unit Duplicated master indoor units in a group.

CODE: L07  
PROBLEM: Indoor unit in a group of units previously addressed as a single unit - check addressing. 

CODE: L08  
PROBLEM: Indoor units addresses not set - check addressing. 

CODE: L09  
PROBLEM: Indoor units capacity not set. 

CODE: L29  
PROBLEM: Outdoor unit IPDU error (Number of detected IPDU units is reduced). 

CODE: L30  
PROBLEM: Input on indoor PCB CN80 circuit for 1 minute .

CODE: L31  
PROBLEM: Outdoor unit PCB error. 

CODE: P01  
PROBLEM: Indoor unit fan motor error. 

CODE: P03  
PROBLEM: Outdoor unit High discharge temperature (TD1 exceeded 115°C). 

CODE: P04  
PROBLEM: Outdoor unit High pressure switch activated (Detected by high temperature on TE sensor on digital/super digital inverter units). 

CODE: P07  
PROBLEM: Outdoor unit PCB heat sink overheated (Temperature over 90°C recorded). 

CODE: P10  
PROBLEM: Indoor unit Float switch activated.

CODE: P12  
PROBLEM: Indoor unit fan motor error - detected by feedback circuit. 

CODE: P19  
PROBLEM: Wrong change in temperature recorded (4 way valve error). 

CODE: P22  
PROBLEM: Outdoor unit fan motor IPDU error. 

CODE: P26  
PROBLEM: Outdoor unit Giant transistor short circuit. 

CODE: P29  
PROBLEM: Outdoor unit Compressor error detected by feedback circuit. 

CODE: P30  
PROBLEM: Indoor unit Group control follower unit error / duplicated central control addresses. 

CODE: P31  
PROBLEM: Indoor unit PCB error. 

CODE: C05  
PROBLEM: Central control Sending error in TCC-Link central control device. 

CODE: C06  
PROBLEM: Central control Receive error in TCC-Link central control device. 

CODE: C12  
PROBLEM: Batch alarm for general purpose equipment interface.



Related Error Code Pages:
Toshiba Air Conditioner Error Codes, Toshiba Microwave Error Codes, Toshiba Television Error Codes,

Related Troubleshooting Pages:
Toshiba Air Conditioner Troubleshooting, Toshiba Microwave Troubleshooting, Toshiba Television Troubleshooting,

Related Repair Pages:
Toshiba Air Conditioner Repairs, Toshiba Microwave Repairs, Toshiba Television Repairs,

Related Parts Pages:
Toshiba Air Conditioner Parts, Toshiba Microwave Parts, Toshiba Television Parts,

Related Price Pages:
Toshiba Air Conditioner Prices, Toshiba Microwave Prices, Toshiba Television Prices,

Related Pages:
local ac services, heating and cooling, residential ac repair, air conditioning repair, air conditioner for sale near me,


Toshiba Air Conditioner Error Codes

Toshiba Air Conditioner fault codes

Toshiba Air Conditioner diagnostic codes

Toshiba Air Conditioner error symbols

Toshiba Air Conditioner common faults


Product Reviews:

So far I have really enjoyed this appliance. I had to modify the window pie
So far I have really enjoyed this appliance. I had to modify the window piece as I had a narrow window, but with a roto-zip, I cut it down about 1". I have it set on 74 degrees and the fan and AC kick on alternately to keep the room cool.
Published: June 23, 2020
Bronwyn
Source: homedepot.com

I have two of these unit and both of them work very well! We have one runni
I have two of these unit and both of them work very well! We have one running in a large den and it cools it down very well! The other unit we run in each of our kids rooms prior to bed time and it cools their room down fast. There is a built in thermometer in our daughters baby cam and it goes from high 70s low 80s to 70 in around 45 minutes. After bed time we roll one into our room for use overnight. It works really well and honestly we don't even notice it during the night. I really appreciate the on/off button for the LCD on the unit. This prevents having a bright green light in your bedroom at night. I can't speak to its ability to dehumidify as I have used the feature.
Published: May 12, 2020
TheGarciaFamily
Source: homedepot.com

We bought this to cool off our bedrooms while we were waiting for parts for
We bought this to cool off our bedrooms while we were waiting for parts for our AC system. Easy to install easy to move around and it works wonderfully. I would recommend this to anyone who needs a portable AC unit when they're in a pinch. Especially if you live in Florida.
Published: September 10, 2019
jacks
Source: homedepot.com

This is a great AC unit if you're looking for portable and your place
This is a great AC unit if you're looking for portable and your place isnt too big/directly facing the sun. This unit easily keeps my 750 sq ft apartment cool during the hot days. Easy to use, remote is great, and the on/off cycle when ambient temp is correct, is great! Yes it's a bit loud, but not horrible.
Published: June 22, 2020
HHH
Source: homedepot.com

Great machine. Nice white and clean. Great dehumifying. The tube was really
Great machine. Nice white and clean. Great dehumifying. The tube was really hot so I got a Cool-Aide and that took care of the issue (see the photo of the tube insulator attached). The tube went from 120 degrees down to 80 degrees! Didn't want to heat the very room I was cooling. It is a good product and keeps the room cool.
Published: June 3, 2020
Haley
Source: homedepot.com

Visa MasterCard

Site Secured By The Website Guardian
TOP