Hayward Calentadores de piscina Códigos de error
Hayward Calentadores de piscina Códigos de error

Hayward Calentadores de piscina Códigos de error

Si está buscando ayuda para arreglar su Pool Heaters Hayward, ¡no busque más! Nuestra guía completa de códigos de error del Pool Heaters Hayward explicará problemas comunes, brindará consejos y le mostrará cómo leer los códigos de error de su modelo.

Código: LO Problema: Interruptor de presión.
FIX:
Verifique que la bomba está funcionando. ENCIENDA LA BOMBA.
Revise el cableado y las conexiones del interruptor. INSPECCIONE LOS CABLES PARA VER SI HAY TORCEDURAS O DAÑOS POR ROEDORES. INSPECCIONE LOS TERMINALES PARA VER SI HAY ROTURAS O CORROSIÓN.
COMPROBAR EL FLUJO DE AGUA. LIMPIAR EL FILTRO, LAS BASES DE LA BOMBA, EL IMPULSOR PARA VER SI HAY OBSTÁCULOS.
Interruptor de presión defectuoso. Reemplace el interruptor de presión.

CÓDIGO: BO
PROBLEMA: Operación de paso.
FIX:
COMPROBAR 2 INTERRUPTORES DIP EN LA PARTE POSTERIOR DEL MÓDULO DE CONTROL. 2 INTERRUPTORES DIP DEBEN ESTAR ACTIVADOS PARA EL FUNCIONAMIENTO REMOTO. PASAR A DESACTIVADO SI NO SE UTILIZA EL MANDO A DISTANCIA.

CÓDIGO: SI
PROBLEMA: FALLO DE ENTRADA.
FIX:
Asegúrese de que las válvulas de suministro de gas están abiertas. Compruebe que el contador de gas, el regulador de gas y la válvula de gas están abiertos.
COMPROBAR EL SUMINISTRO DE GAS BAJO. LA PRESIÓN DE GAS DE ENTRADA DEBE SER SUPERIOR A LA MÍNIMA INDICADA EN LA PLACA DE CARACTERÍSTICAS.
Revise el cableado y las conexiones del encendedor. INSPECCIONE LOS CABLES PARA VER SI HAY TORCEDURAS O DAÑOS POR ROEDORES. INSPECCIONE LOS TERMINALES PARA VER SI HAY ROTURAS O CORROSIÓN.
Revise el cableado y las conexiones de la válvula de gas. INSPECCIONE LOS CABLES PARA VER SI HAY TORCEDURAS O DAÑOS POR ROEDORES. INSPECCIONE LOS TERMINALES PARA VER SI HAY ROTURAS O CORROSIÓN.

Código: SF
Problema: Fallo en la entrada del sensor de temperatura.
FIX:
Compruebe el cableado y las conexiones de los sensores. INSPECCIONE LOS CABLES PARA VER SI HAY TORCEDURAS O DAÑOS POR ROEDORES. INSPECCIONE LOS TERMINALES PARA VER SI HAY ROTURAS O CORROSIÓN.
Sensor defectuoso. Sustituya el sensor de temperatura.

Código: HS
Problema: Sobrecalentamiento.
FIX:
TEMPERATURA DEL AGUA DE LA PISCINA ygt; 104°. VERIFICAR EL PUNTO DE AJUSTE DEL TERMOSTATO REMOTO.
COMPROBAR EL CAUDAL DE AGUA. VERIFICAR QUE EL CAUDAL DE AGUA ES MÍNIMO DE 25 GPM.

CÓDIGO:HF
PROBLEMA:FALLO DE SENTIDO DE LLAMA.
FIX: REPLANTEAR IGNITADOR.



Páginas de códigos de error relacionados:
Hayward Calentadores de piscina Códigos de error,

Páginas de resolución de problemas relacionadas:
Hayward Calentadores de piscina Solución de problemas,

Páginas de reparación relacionadas:
Hayward Calentadores de piscina Refacción,

Páginas de piezas relacionadas:
Hayward Calentadores de piscina Partes,

Páginas de precios relacionadas:
Hayward Calentadores de piscina Precios,


Hayward Calentadores de piscina Códigos de error

Hayward Calentadores de piscina códigos de avería

Hayward Calentadores de piscina códigos de diagnóstico

Hayward Calentadores de piscina símbolos de error

Hayward Calentadores de piscina fallas comunes


Product Reviews:

Finally replaced our hold Hayward heater after 15 years (it actually explod
Finally replaced our hold Hayward heater after 15 years (it actually exploded, otherwise, we'd probably still be using it). This is a great replacement, seems to heat a little faster than the old one. A little smaller. The only thing I wish that Hayward had done was not to change the layout of the connections. Had to replumb and redo gas line.
Published: November 9, 2019
Tinyt1553
Source: amazon.com

We have a standalone spa with this 200,000 BTU gas heater. To me, this is s
We have a standalone spa with this 200,000 BTU gas heater. To me, this is superior to the typical electric heated self-contained systems because it heats cold tap water to 104 degrees in about 30 minutes in our 250 gallon spa. In CA, gas is cheap compared to electricity for heating. With an insulating cover, we get in and run the heater for only 6 minutes to get from 94 to 100 degrees. That way, it's not scalding hot when you get in, but cranks up fast.
Published: August 21, 2019
Frank Yee Danville, CA USA
Source: amazon.com

Purchased in Sept. 2016, had to replace the heat exchanger once, but we wer
Purchased in Sept. 2016, had to replace the heat exchanger once, but we were not sure if it was too much water flow, or chemical imbalance. But, this unit heats my 33,000 gallon (DE filter system) very quickly, and reliably. The regional rep (Greg) was very easy to deal with and made the experience more understandable as far as issues and made replacing the heat exchanger a fair and straightforward one. Just a word of caution - overly high water flow into the heater can and likely will cause the coils to deteriorate, and this can happen in less than a year. So, be sure your pool pump is sending a reasonable flow through the system (you can call Hayward for details) as well as balancing your chems. The replacement heat exchange assembly costs about $1,100 (plus $200-400 for labor), so replacing can approach the cost of an entirely new heater.
Published: March 5, 2018
TomHunter1968 Newport Beach, CA
Source: amazon.com

Bought this to replace an old broken rusted out Hayward H400IDL that was ab
Bought this to replace an old broken rusted out Hayward H400IDL that was about 15 years old. My old heater seemed to breakdown every 3 months or so. I’m hoping this one will be more reliable. The installation wasn’t to bad I did it myself but the biggest negative was when I called Hayward and they told me the H400FDN was an exact replacement that wouldn’t need plumbing adjustments to fit but that wasn’t the case both the water and gas connections had to be reworked to line up. Nothing to difficult but it required a trip to Lowe’s to get everything working. Overall it seems like a good heater although it doesn’t look like the picture shown on amazon? the control panel is completely different then what is shown. Also don’t forget to register online for your warranty and apply for a rebate with your local gas company I got an extra $300 off with a rebate from SoCalGas.
Published: July 24, 2020
Matthew
Source: amazon.com

The Hayward H-Series H250FDN is extremely reliable and energy efficient. It
The Hayward H-Series H250FDN is extremely reliable and energy efficient. It marries high performance with environmentally responsible low NOx emissions and can provide energy savings of up to 18% compared to other similar pool heaters.
Published: January 6, 2020
Heidi Scrimgeour
Source: toptenreviews.com

Visa MasterCard

Site Secured By The Website Guardian
CIMA