Rinnai Calentador de agua Códigos de error
Rinnai Calentador de agua Códigos de error

Rinnai Calentador de agua Códigos de error

Si está buscando ayuda para arreglar su Water Heater Rinnai, ¡no busque más! Nuestra guía completa de códigos de error del Water Heater Rinnai explicará problemas comunes, brindará consejos y le mostrará cómo leer los códigos de error de su modelo.

Código: 02
PROBLEMA: No funciona el quemador durante el modo de protección contra la congelación.
FIX: Llame a un fontanero.

CÓDIGO: 03
PROBLEMA: Interrupción de la alimentación durante el llenado de la bañera
FIX: Cierre todos los grifos de agua caliente. Pulse el botón de encendido/apagado dos veces. Vuelva a abrir el agua caliente y pruebe. Es posible que tenga que intentar esto un par de veces para restablecer el sistema.

Código: 10
PROBLEMA: Aspiración o suministro de aire bloqueado
FIX: Busque bloqueos tanto en la entrada como en la salida de humos. ¿Están bien conectados los componentes de ventilación? Compruebe el collarín de condensación. ¿Está suelto o mal instalado?

CÓDIGO: 11
PROBLEMA: Problemas de encendido
FIX: ¿Está el gas abierto? Compruebe en el calentador de agua, el contador de gas o la bombona.

Código: 12
PROBLEMA: Fallo de llama
FIX: Compruebe la alimentación eléctrica. ¿Hay conexiones sueltas? ¿Cuál es la tensión? ¿Hay caídas de tensión? ¿Está conectado el cable de la varilla de la llama? ¿Hay problemas de acumulación de carbón en la varilla de la llama?

Código: 14
PROBLEMA: Fusible térmico
FIX: Compruebe si hay restricciones en el flujo de aire.

CÓDIGO: 16
PROBLEMA: Calentamiento por exceso de temperatura
FIX: Compruebe si hay atascos u obstrucciones en la cámara de combustión, la tubería de escape y el intercambiador de calor
CODE: 32
PROBLEMA: Fallo del sensor de temperatura del agua saliente
FIX: Examine cuidadosamente el sensor. Busque daños y acumulación de sarro. Probablemente tenga que reemplazar el sensor si la limpieza no ayuda.

Código: 33
PROBLEMA: Fallo del sensor de temperatura de salida del intercambiador de calor
FIX: Examine cuidadosamente el sensor. Busque daños y acumulación de sarro y asegúrese de que el aspa del ventilador está ajustada al eje del motor y no está dañada. Probablemente tenga que reemplazar el sensor si la limpieza no ayuda.

Código: 34
PROBLEMA: Fallo del sensor de temperatura del aire de combustión
FIX: Examine cuidadosamente el sensor y el cableado. Busque daños y acumulación de sarro. Probablemente tenga que reemplazar el sensor si la limpieza no ayuda.

Código: 52
PROBLEMA: Señal anormal de la válvula solenoide de modulación
FIX: Compruebe el mazo de cables de la válvula solenoide de gas de modulación para ver si hay terminales sueltos o dañados. Es posible que pueda resolver el problema apretando los terminales sueltos.

Código: 61
PROBLEMA: Fallo del ventilador de combustión
FIX: ¿Hay problemas con el mazo de cables? Tal vez se ha dañado o tiene conexiones sueltas? ¿Hay algún problema con la resistencia del bobinado del motor?

Código: 65
PROBLEMA: Fallo en el control del flujo de agua
FIX: Cierre inmediatamente el agua y suspenda la función de llenado de la bañera. Luego llame a un fontanero.

Código: 71
PROBLEMA: Fallo en el circuito de la válvula solenoide
FIX: Probablemente necesite sustituir la válvula solenoide. Primero compruebe el mazo de cables de todos los solenoides. Mida la resistencia de cada bobina de la válvula solenoide.

Código: 72
PROBLEMA: Fallo del dispositivo de detección de llama
FIX: Compruebe si la varilla de la llama está tocando la llama cuando la unidad se dispara. Examine el cableado de la varilla de la llama para ver si está dañado. Limpie la varilla de la llama con papel de lija.



Páginas de códigos de error relacionados:
Rinnai Calentador de agua Códigos de error,

Páginas de resolución de problemas relacionadas:
Rinnai Calentador de agua Solución de problemas,

Páginas de reparación relacionadas:
Rinnai Calentador de agua Refacción,

Páginas de piezas relacionadas:
Rinnai Calentador de agua Partes,

Páginas de precios relacionadas:
Rinnai Calentador de agua Precios,


Rinnai Calentador de agua Códigos de error

Rinnai Calentador de agua códigos de avería

Rinnai Calentador de agua códigos de diagnóstico

Rinnai Calentador de agua símbolos de error

Rinnai Calentador de agua fallas comunes


Product Reviews:

My husband and I installed this ourselves. We went from an electric 50 gall
My husband and I installed this ourselves. We went from an electric 50 gallon water heater to this. First, I did a lot of research, looked up the codes in our county and city and made a plan. I bought this tankless water heater in the summer, It took me several months to install as I had to remodel the room it was going into first. The hardest part was cutting a hole through some bricks to make sure the venting would fit everything else was pretty easy. I just ran a gas line and ordered the proper venting. The water lines were pretty much where they needed to be. Once all the lines were in place the heater went up in a day. We have been using the heater for about a month now. The outside temp got down to the teens for a few weeks. I can honestly say I love the heater. I do not have to worry about saving any hot water for my husbands shower because there is a never ending supply. We had people over and they also enjoyed the ability to shower without waiting for the water to heat up. The guest shower is a little farther from the heater and they did say the faucet took a little longer to demonstrate the change in temp. Not sure if that is due to the heater or the faucet. My kitchen is the farthest from the heater and it does take a couple minutes to get hot water to the faucet. I have found that if I rinse the dishes with hot water, then the dishwasher has plenty of hot water. My gas bill did not go up much over the last month (it was a lot colder and the increase could have been from the house heater). I have not gotten an electric bill yet but I bet it will be way less. The heater is not even as loud as my washer or dryer, so I am not sure why others have said it was loud. I will never go back to a tank system.
Published: December 31, 2015
Roylene Rangel
Source: amazon.com

I purchased this over a year ago but I just got around to installing it. I
I purchased this over a year ago but I just got around to installing it. I installed it in my basement. I put a 10" extension directly above it, a 45 degree elbow, and 11' of extensions to get it out beyond my deck. It seems to be running fine. I put a small slope on the extension to allow the condensation to run out instead of back into the unit. So I didn't put an condensation system on the side pipe. So far it's working great. It does take a little while to reach equilibrium but this isn't my first On-Demand hot water heater and this was expected. I keep it set at 120 F but I doubt that's what's coming out of the faucets. I'm not sure why that is but it's hot enough and the flow is pretty good so I'm not complaining. Now I'm just waiting for my first whole electric bill to see how much savings I'll get from getting rid of my electric hot water heater.
Published: January 16, 2015
Good HWH
Source: amazon.com

I have this tankless water heater for the past 4 years. I have never had an
I have this tankless water heater for the past 4 years. I have never had any problem . The only problem that i have is that my water bill went up..... my kids and wife stay longer in the shower and before the hot water would run out and they would get out of the shower . Be aware hot water won't run out but water bill will run up!
Published: January 29, 2021
Leandro Roselli
Source: amazon.com

The Rinnai R85 that came w my house started leaking at 12yrs old so I bough
The Rinnai R85 that came w my house started leaking at 12yrs old so I bought the RL75iN. My goal was to buy the closest model to the older model so I could use the existing exhaust pipe, water connections, and gas connection, as I'm not the handy type. It all went fairly smooth since the exhaust, water, and gas connections are in the same spot on the new model. Just a WARNING if you attempt this the inner metal layer of the exhaust pipe corroded/welded about 6 pieces together, in the process of pulling out the old R85 a couple of the black seals broke (brittle from age) that seal the outer plastic exhaust pipe together, due to this corrosion/welding I had to buy all 6 pieces again (I used something like WD-40 to bust apart the corrosion seams, DON'T do this!!! the pieces remained welded together plus the WD-40 warps all of the seals), which ment 4 more days without hot water and expedited shipping costs for these parts. Don't make my mistake, if you're doing a retro-fit make sure your existing exhaust pipe isn't damaged and if it is get those pieces ordered when you order the RL75iN. I read a lot of reviews before doing this, I used white ptfe tape on the water, and yellow ptfe on the gas threads. Best hint I came across was from old timer plumber and also used Rectorseal #5 on top of the taped threads. Worked great, piece of mind was worth the few bucks for the #5. Good luck! Also it is really handy to have a buddy hold up the unit while you bolt it to the wall.
Published: January 6, 2018
JTM
Source: amazon.com

As for the performance, we have a bit smaller house with only a few feet of
As for the performance, we have a bit smaller house with only a few feet of water line between this unit and out faucets. It takes about 30 seconds for the water to come to temp. We absolutely love it!
Published: May 28, 2018
MAGA2020
Source: amazon.com

Visa MasterCard

Site Secured By The Website Guardian
CIMA