Focus te invita a descubrir su universo, desde el inicio de la idea, pasando por las oficinas administrativas, hasta el taller de producción, donde el savoir faire entra en juego. Los trabajadores metalúrgicos de Focus construyen a medida los accesorios para cada estufa y chimenea, haciendo que cada modelo sea único. El trabajo de sus manos da vida al trabajo de diseño e investigación, transformando lo intangible en tangible.


Calentador de patio a gas Códigos de error


Chimenea de gas Códigos de error

Problem; The main burner does not ignite when called for. 
Possible Cause: The gas valve may not be on.  
Solution: Check that the gas control knob is in the "ON" position. 

Problem; The main burner does not ignite when called for. 
Possible Cause: Thermostat is not calling for heat. 
Solution: Adjust the thermostat several degrees above ambient temperature. 

Problem; The main burner does not ignite when called for. 
Possible Cause: Problem with gas valve.  
Solution: Use a DC voltmeter to measure the voltage across the TPTH and TP terminals. Main operator voltage: Open circuit = 325mV Closed circuit = 100mV If voltage is not present, check the control circuit for proper operation. If proper control system voltage is present, replace the gas control. 

Problem; Spark will not light the pilot after repeatedly pressing the spark ignitor. 
Possible Cause: Defective piezo ignitor.  
Solution: Check connections to ignitor. If ignitor connections are good but no spark, replace ignitor. 

Problem; Spark will not light the pilot after repeatedly pressing the spark ignitor. 
Possible Cause: Broken spark electrode.  
Solution: Check for broken ceramic insulation, replace electrode if broken. 

Problem; Spark will not light the pilot after repeatedly pressing the spark ignitor. 
Possible Cause: Misaligned spark electrode.  
Solution: If spark is not arcing from electrode to pilot, loosen the screws on the pilot base adjust and tighten. 

Problem; Pilot will not remain lit. 
Possible Cause: Problem with thermocouple circuit. 
Solution: Check for proper connection of the thermocouple to the rear of the valve. If loose, fully tighten. Check pilot for full flame impingement around thermocouple. If flame is too small, check gas pressure, adjust pilot rate screw, check pilot head for damage. Check thermocouple voltage at valve. It must be greater than 5 mV. If low, replace thermocouple. 

Problem; Pilot will not remain lit. 
Possible Cause: Air in gas line (pilot dies while knob is depressed). 
Solution: Bleed line. Check gas line pressure. Contact dealer. 

Problem; Burners will not remain lit. 
Possible Cause: Problem with thermopile circuit. 
Solution: Check gas line pressure. Check for flame impingement on thermopile. If low, see "Pilot will not remain lit". Check thermopile for minimum of 300 mV when burner is switched on. Check wiring to thermostat for breaks. BV ONLY: Check for spillage at draft hood that may trip spill switch 

Problem; Flame lifting. 
Possible Cause: Leak in vent pipe. 
Solution: Check for leaks in vent connections. 

Problem; Flame lifting. 
Possible Cause: Improper vent configuration.  
Solution: Check vent configuration with manual. 

Problem; Flame lifting. 
Possible Cause: Terminal may be recirculating flue gases. 
Solution: Check to see if terminal is on correctly. May need to install high wind termination cap. Contact dealer. 

Problem; Glass fogs up.  
Possible Cause: Normal Condition: after the appliance warms up the glass will clear. **Due to additives in gas, glass may get hazy during operation** Clean as needed. 
Solution: N/A 

Problem; Blue Flames. 
Possible Cause: Normal during start up: flames will yellow as the fireplace heats up. 
Solution: N/A 

Problem; Flames are burning "dirty" or sooting 
Possible Cause: Flame impingement  
Solution: Check log positioning. Increase primary air by opening the venturi shutter and/or by opening the vent restrictor.  

Problem; Remote control doesn’t work. 
Possible Cause: Problem with the remote. 
Solution: One or more of the batteries are dead. See remote control instructions. 

Problem; Remote control doesn’t work. 
Possible Cause: Problem with fireplace. 
Solution: The on/off switch is turned to OFF. The gas control valve is turned to PILOT or OFF. The pilot has gone out. 

Problem; BV ONLY: Insufficient air for combustion. 
Possible Cause: Air tight house. 
Solution: Supply make up air to the unit. 

Problem; BV ONLY: Insufficient air for combustion. 
Possible Cause: A vacuum in room due to other air-moving device. 
Solution: Supply make up air to the unit.



Focus Códigos de error del aparato

Focus códigos de avería del aparato

Focus códigos de diagnóstico del aparato

Focus símbolos de error del aparato

Focus fallos comunes del aparato


Reseñas de productos:

Focus Fireplaces Ltd York have just fitted our new log burner, hearth &
Focus Fireplaces Ltd York have just fitted our new log burner, hearth & beam. They have been absolutely fantastic from choosing the fire to fitting. We are extremely pleased with the workmanship and professional service throughout and nothing was too much trouble. Thank you so much, we would definitely recommend Focus Fireplaces.
Publicado: July 31, 2021
Richard Chester
Fuente: focusfireplacesyork.co.uk

Had our new fireplace and fire fitted yesterday. Highly delighted with the
Had our new fireplace and fire fitted yesterday. Highly delighted with the end product and finish. Would be very happy to recommend Focus Fireplaces to anyone.
Publicado: November 30, -0001
Phil Bradish
Fuente: focusfireplacesyork.co.uk

We had Focus Fireplaces round recently to build a stud wall and fit a stove
We had Focus Fireplaces round recently to build a stud wall and fit a stove within an alcove of the stud wall. They were knowledgeable and helpful from start to finish, providing clear options. The installation was quick, to schedule and done to a high standard. Would definitely recommend.
Publicado: November 30, -0001
Craig Morrison
Fuente: focusfireplacesyork.co.uk

New fireplace installed last week and we’re very pleased with result
New fireplace installed last week and we’re very pleased with result. Great choice of many styles in the showroom and very helpful staff who knew what they were talking about so useful advice and no pressure….even over multiple visits.
Publicado: May 31, 2021
Roz B
Fuente: focusfireplacesyork.co.uk

Focus fireplaces have been brilliant from start to finish. The showroom tea
Focus fireplaces have been brilliant from start to finish. The showroom team were friendly and helpful, with no sales pressure, just wise advice. Liz prepared multiple quotes to help us make our decisions.
Publicado: August 31, 2021
Catherine Spedding
Fuente: focusfireplacesyork.co.uk

Visa MasterCard

Site Secured By The Website Guardian
CIMA