Payne Furnace Error Codes
Payne Furnace Error Codes

Payne Furnace Error Codes

If you're looking for help fixing your Payne Furnace, look no further! Our comprehensive Payne Furnace error code guide will explain common issues, provide tips, and show you how to read your model's error codes.

CODE: RED LED1 ON. 
PROBLEM: Furnace is operating in emergency heat. 

CODE: RED LED2 ON. 
PROBLEM: The microprocessor has malfunctioned. To reset: Put setup switch "SW-1" in the "ON" position and jumper thermostat terminals "R", "W/W1" and "Y/Y2" simultaneously with the door switch pushed in and power to the unit "ON". Disconnect jumper and place setup switch in the "OFF" position. If LED2 reappears, replace main control board. 

CODE: YELLOW LED3 ON. 
PROBLEM: Furnace is operating in high heat. 

CODE: GREEN LED4 ON. 
PROBLEM: Furnace is operating in low heat. 

CODE: RED LED2 FLASHING. 
PROBLEM: Line voltage polarity is reversed. 

CODE: 11. 
PROBLEM: NO FAULT IN RECENT HISTORY DISPLAY- Indicates no faults have occurred within the last five cycles. To read recent fault history, put setup switch "SW-1" in the "ON" position. To clear recent fault history, put setup switch "SW-1" in the "ON" position and jumper thermostat terminals "R", "W/W1" and "Y/Y2" simultaneously until an "11" is flashed. 

CODE: 12. 
PROBLEM: BLOWER CALIBRATION LOCKOUT- Indicates RPM calculated for low heat was less than 250 RPM or greater than 1300 RPM on two successive attempts. Auto reset after three hours. Reset power and refer to fault #44 section. 

CODE: 13. 
PROBLEM: LIMIT SWITCH LOCKOUT- Indicates the occurrence of 10 successive limit trips during high heat or three successive limit trips during low heat. Auto reset after three hours. Check for *Improper or misaligned limit and/or limit shield. *Improper high or low heat gas input adjustment. *Stuck high heat solenoid in gas valve. 

CODE: 14. 
PROBLEM: IGNITION LOCKOUT- Control will auto-reset after three hours. Refer to #34. 

CODE: 21. 
PROBLEM: INVALID MODEL SELECTION- Indicates model plug is missing or incorrect. See wiring diagram for correct connector jumper location. 

CODE: 22. 
PROBLEM: SETUP ERROR- Indicates setup switch "SW-1" or "SW-6" is positioned improperly. The following combinations will cause the fault: *Thermostat call with "SW-1" "ON", or Thermostat call with "SW-6" "ON", or "SW-1" and "SW-6" both "ON" together. 

CODE: 23. 
PROBLEM: INVALID BLOWER AIRFLOW SELECTION- Indicates improper "A/C" or "CF" switch setting. The 042 and 14 units can deliver 1-1/2 to 3-1/2 tons A/C and 600 to 1400 CFM for continuous fan. The 060 and 20 unit can deliver 2 to 5 tons A/C and 800 to 2000 CFM for continuous fan. If code is flashing, unit will default tp closest allowable airflow. 

CODE: 24. 
PROBLEM: SECONDARY VOLTAGE FUSE IS OPEN Check for: - Short circuit in secondary voltage (24VAC) wiring. PRESSURE SWITCH DID NOT CLOSE OR REOPENED - If open longer than five minutes, inducer shuts off for 15 minutes before retry. Check for: - Excessive wind. 

CODE: 31. 
PROBLEM: Proper vent sizing -- Defective inducer motor - Low inducer voltage (115VAC) - Defective pressure switch - Inadequate combustion air supply - Restricted vent - Disconnected or obstructed pressure tubing - Low inlet gas pressure (if LGPS used) If it opens during blower ondelay period, blower will come on for the selected blower off-delay. 

CODE: 33. 
PROBLEM: LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset. Check for: - Restricted vent - Proper vent sizing - Loose blower wheel - Excessive wind - Dirty filter or restricted duct system. - Defective blower motor or capacitor. - Defective switch or connections. - Inadequate combustion air supply (Flame Roll-out Switch open). 

CODE: 34. 
PROBLEM: IGNITION PROVING FAILURE - Control will try three more times before lockout #14 occurs. If flame signal lost during blower on-delay period, blower will come on for the selected blower off-delay. Check for: - Control ground continuity - Flame sensor must not be grounded - Oxide buildup on flame sensor (clean with fine steel wool) - Proper flame sense microamps (.5 microamps D.C. min., 4.0 - 6.0 nominal). - Gas valve defective or gas valve turned off - Manual valve shut-off - Defective Hot Surface Ignitor - Low inlet gas pressure - Inadequate flame carryover or rough ignition - Green/Yellow wire MUST be connected to furnace sheet metal. 

CODE: 41. 
PROBLEM: BLOWER OUTSIDE VALID SPEED RANGE- Indicates the blower is not operating at the calculated RPM. If this fault occurs in conjunction with fault #44 check wiring to motor otherwise refer to the trouble-shooting guide. 

CODE: 42. 
PROBLEM: INDUCER OUTSIDE VALID SPEED RANGE- Indicates the inducer is not operating at the calculated RPM. Or it has not started within 10 seconds after a call for heat. Check wiring to motor otherwise refer to the troubleshooting guide. 

CODE: 43. 
PROBLEM: PRESSURE SWITCH CALIBRATION FAULT- Indicates the low and high pressure switch "make" points during high heat purge are not within calibration range. Check for: -Plugged condensate drain Water in vent piping, possibly sagging pipe -Improper pressure switch wiring or pressure switch tubing connections -Failed or "out of calibration" pressure switches. 

CODE: 44. 
PROBLEM: BLOWER CALIBRATION FAULT- Indicates the calculated blower speed is below 250 or above 1300 RPM. Unit will default to low or high heat mode if possible. If this fault occurs in conjunction with fault #41, check wiring to motor otherwise refer to the trouble shooting guide. If this fault occurs by itself, check for undersized ductwork, or excessive static caused by a dirty filter, or closed registers. 

CODE: 45. 
PROBLEM: CONTROL CIRCUITRY LOCKOUT -Auto-reset after one hour lockout due to; - Gas valve relay stuck open - Flame sense circuit failure - Software check error Reset power to clear lockout. Replace control if status code repeats.



Related Error Code Pages:
Payne Air Conditioner Error Codes, Payne Furnace Error Codes,

Related Troubleshooting Pages:
Payne Air Conditioner Troubleshooting, Payne Furnace Troubleshooting,

Related Repair Pages:
Payne Air Conditioner Repairs, Payne Furnace Repairs,

Related Parts Pages:
Payne Air Conditioner Parts, Payne Furnace Parts,

Related Price Pages:
Payne Air Conditioner Prices, Payne Furnace Prices,

Related Pages:
furnace quotes, house furnace service, furnace companies in my area, furnace contractor, furnace repair services,


Payne Furnace Error Codes

Payne Furnace fault codes

Payne Furnace diagnostic codes

Payne Furnace error symbols

Payne Furnace common faults


Product Reviews:

Payne delivers a consistent level of high efficiency heating and cooling pr
Payne delivers a consistent level of high efficiency heating and cooling products for Canadian consumers. Despite the brand's limited selection, the furnaces that they do offer are dependable and guarantee to deliver expert comfort for almost any Canadian home.
Published: December 3, 2019
furnaceprices.ca
Source: furnaceprices.ca

We have recently relocated to a new house where we realized that the existi
We have recently relocated to a new house where we realized that the existing furnace was actually over 20 years old and had to get a new one. I looked at several options and landed on the two-stage Payne furnace. We’ve used it for about a year, and it has been highly efficient. I couldn’t be happier. I would happily recommend this furnace to a friend.
Published: September 3, 2020
pickhvac.com Michigan
Source: pickhvac.com

I have had this furnace for approximately two years now. I am satisfied wit
I have had this furnace for approximately two years now. I am satisfied with it as it heats up well, but I sometimes wish that it could do better. If I were to purchase a furnace again, I would buy the same brand but may go with a different model.
Published: December 3, 2020
pickhvac.com AZ
Source: pickhvac.com

I am delighted with this furnace. I bought it a little over a year ago. I p
I am delighted with this furnace. I bought it a little over a year ago. I previously used a brand that wouldn’t heat past 70. However, with the Payne furnace, my house is now warm and inviting. I would gladly recommend it to anyone in search of a good furnace.
Published: November 3, 2020
pickhvac.com Chicago
Source: pickhvac.com

I purchased this furnace a little over a year ago. I first disliked how exp
I purchased this furnace a little over a year ago. I first disliked how expensive it was, but the salesman assured me that it would be good for a split level house. However, this is not so; it barely regulates the air in my basement. I have not had to repair it though.
Published: October 3, 2020
pickhvac.com Edmonton
Source: pickhvac.com

Visa MasterCard

Site Secured By The Website Guardian
TOP