CODE: Unit will not operate, 
PROBLEM: Power disconnected or loose connection. 
FIX: Check power supply to unit. Check voltage at contactor. 

CODE: Unit will not operate, 
PROBLEM: Blown fuse / breaker tripped. 
FIX: Replace fuses/reset breaker. 

CODE: Unit will not operate, 
PROBLEM: Thermostat out of calibration is set too high. 
FIX: Reset. 

CODE: Unit will not operate, 
PROBLEM: Contactor defective. 
FIX: Check for 24VAC at contactor coil - replace if open. 

CODE: Unit will not operate, 
PROBLEM: Transformer defective. 
FIX: Check wiring - replace transformer. 

CODE: Unit will not operate, 
PROBLEM: High pressure control open (if provided). 
FIX: Reset - see high pressure connection. 

CODE: Outdoor fan on; Compressor off. 
PROBLEM: Run or start capacitor defective. 
FIX: Replace. 

CODE: Outdoor fan on; Compressor off. 
PROBLEM: Start relay defective. 
FIX: Replace. 

CODE: Outdoor fan on; Compressor off. 
PROBLEM: Loose wire. 
FIX: Check for correct voltage at compressor - check and tighten all connections. 

CODE: Outdoor fan on; Compressor off. 
PROBLEM: Compressor stuck, grounded or open motor winding, open internal overload. 
FIX: Wait at least 2 hours for overload to reset; if still open, replace the compressor. 

CODE: Too little cooling. 
PROBLEM: Low voltage condition. 
FIX: Add start kit components. 

CODE: Too little cooling. 
PROBLEM: Improperly sized unit. 
FIX: Recalculate load. 

CODE: Too little cooling. 
PROBLEM: Improper indoor airflow. 
FIX: Check-should be approximately 400 CFM per ton. 

CODE: Too little cooling. 
PROBLEM: Incorrect refrigerant charge. 
FIX: Charge per procedure in installation manual. 

CODE: Too little cooling. 
PROBLEM: Air, non-condensables or moisture in system. 
FIX: Recover refrigerant. 

CODE: Compressor operates in short cycles. 
PROBLEM: Incorrect voltage. 
FIX: At compressor terminals, voltage must be +/10% of nameplate marking when unit is operating. 

CODE: Compressor operates in short cycles. 
PROBLEM: Defective overload protector. 
FIX: Replace - check for correct voltage. 

CODE: Compressor operates in short cycles. 
PROBLEM: Refrigerant undercharge. 
FIX: Add refrigerant. 

CODE: High head pressure; Low suction pressure. 
PROBLEM: Restriction in liquid line, expansion device or filter drier. 
FIX: Remove or replace defective component. 

CODE: High head pressure; Low suction pressure. 
PROBLEM: Lack of sufficient indoor airflow. 
FIX: Clean/check filters, registers, or evaporator coil that may cause a restriction. 

CODE: High head pressure; Normal suction pressure. 
PROBLEM: Dirty outdoor coil. 
FIX: Clean coil. 

CODE: High head pressure; Normal suction pressure. 
PROBLEM: Refrigerant overcharge. 
FIX: Correct system charge. 

CODE: High head pressure; Normal suction pressure. 
PROBLEM: Outdoor fan not running. 
FIX: Repair or replace. 

CODE: High head pressure; Normal suction pressure. 
PROBLEM: Air or non-condensables in system. 
FIX: Recover refrigerant, evacuate and recharge. 

CODE: Low head pressure; High suction pressure. 
PROBLEM: Expansion device stuck in open position. 
FIX: Replace expansion device. 

CODE: Low head pressure; High suction pressure. 
PROBLEM: Defective compressor valves. 
FIX: Replace compressor. 

CODE: Low suction pressure; Compressor cool. Ice on indoor coil. 
PROBLEM: Low indoor airflow. 
FIX: Increase speed of blower or reduce restriction - replace air filter. 

CODE: Low suction pressure; Compressor cool. Ice on indoor coil. 
PROBLEM: Operating below 65F (18C) outdoors. 
FIX: Add low ambient kit. 

CODE: Low suction pressure; Compressor cool. Ice on indoor coil. 
PROBLEM: Moisture in system. 
FIX: Recover refrigerant - evacuate and recharge - replace filter drier. 

CODE: High suction pressure; or fluctuating head and suction pressures. 
PROBLEM: Excessive load. 
FIX: Recheck load calculation. 

CODE: High suction pressure; or fluctuating head and suction pressures. 
PROBLEM: Defective compressor. 
FIX: Replace. 

CODE: High suction pressure; or fluctuating head and suction pressures. 
PROBLEM: TXV hunting. 
FIX: Check TXV bulb clamp - check air distribution on coil - replace TXV. 

CODE: High suction pressure; or fluctuating head and suction pressures. 
PROBLEM: Air or non-condensables in system. 
FIX: Recover refrigerant, evacuate and recharge. 

CODE: Pulsing noise at expansion device or liquid line. 
PROBLEM: Air or non-condensables in system. 
FIX: Recover refrigerant, evacuate and recharge. 

CODE: Registers sweat. 
PROBLEM: Low indoor airflow. 
FIX: Increase speed of blower or reduce restriction - replace air filter.



Páginas de códigos de error relacionados:
Napoleon Aire acondicionado Códigos de error, Napoleon Horno Códigos de error, Napoleon Gas Fireplace Códigos de error, Napoleon Gas Grill Códigos de error,

Páginas de resolución de problemas relacionadas:
Napoleon Aire acondicionado Solución de problemas, Napoleon Horno Solución de problemas, Napoleon Gas Fireplace Solución de problemas, Napoleon Gas Grill Solución de problemas,

Páginas de reparación relacionadas:
Napoleon Aire acondicionado Refacción, Napoleon Horno Refacción, Napoleon Gas Fireplace Refacción, Napoleon Gas Grill Refacción,

Páginas de piezas relacionadas:
Napoleon Aire acondicionado Partes, Napoleon Horno Partes, Napoleon Gas Fireplace Partes, Napoleon Gas Grill Partes,

Páginas de precios relacionadas:
Napoleon Aire acondicionado Precios, Napoleon Horno Precios, Napoleon Gas Fireplace Precios, Napoleon Gas Grill Precios,


Napoleon Aire acondicionado Códigos de error

Napoleon Aire acondicionado códigos de avería

Napoleon Aire acondicionado códigos de diagnóstico

Napoleon Aire acondicionado símbolos de error

Napoleon Aire acondicionado fallas comunes


Product Reviews:

Professional service. From the initial phone call the service was great. Do
Professional service. From the initial phone call the service was great. Do to living in another town they only needed a few photos to give a quote and followed up with a scheduled appointment.
Published: November 30, 2018
Howard &B
Source: napoleonheatingandcooling.com

Quiet as a Mouse! Installed this spring, sometimes do not even hear that it
Quiet as a Mouse! Installed this spring, sometimes do not even hear that it is running.
Published: June 30, 2020
spiketaylor
Source: napoleonheatingandcooling.com

Excellent Cooling! We’ve had our new Napoleon air conditioner for just ov
Excellent Cooling! We’ve had our new Napoleon air conditioner for just over 3 months. This has been the hottest summer in a number of years. Our air conditioner has been on every day except 2 or 3. And our house has never felt cooler. Our old air conditioner never got our second storey cool enough. We always had the ceiling fan and a floor fan on to make us more comfortable. Now, our upstairs is perfect. So much cooler. No fans needed. I would highly recommend my Napoleon AC.
Published: November 30, 2018
DandJ
Source: napoleonheatingandcooling.com

A good investment. Our new air conditioner has been a blessing this year co
A good investment. Our new air conditioner has been a blessing this year considering the summer we have had, it kept us very comfortable.
Published: March 30, 2018
willie76
Source: napoleonheatingandcooling.com

Efficient and quiet. Thank goodness I bought this air conditioner before th
Efficient and quiet. Thank goodness I bought this air conditioner before the extremely hot, humid summer. It was very efficient and quiet and my hydro bills didn't change.
Published: June 30, 2018
Morris
Source: napoleonheatingandcooling.com

Visa MasterCard

Site Secured By The Website Guardian
CIMA